Customization: | Available |
---|---|
After-sales Service: | Quick and Effective After Sales Solution. |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
I. Description
1. Continuous and rapid detection of pile integrity by acoustic transmission method;
2. Ultrasonic method detects internal defects of concrete, such as uncompacted areas, honeycomb voids, quality of joint surface, thickness of surface damage layer, etc.;
3. Ultrasonic-rebound comprehensive method to test the compressive strength of concrete;
4. Ultrasonic method to detect the depth of concrete cracks;
5. Single hole, one transmitter and two receivers to detect the integrity of the hole wall of non-metallic materials such as rock mass and concrete;
6. Geological exploration, testing of mechanical properties of non-metallic materials such as rock mass and concrete.
II. Feature
1. High detection efficiency. It can continuously perform single and double channel pile integrity detection, and the lifting speed can reach 60 meters per minute (20cm distance measurement);
2. Fast and accurate automatic interpretation of acoustic parameters. Real-time dynamic waveform display ensures the efficiency of detection;
3. Humanized software design. The instrument test interface is directly oriented to the user and the engineering test site, and there is helpful information that the user can use conveniently;
4. Graphical display of test results. After the test, the analysis results can be displayed graphically, and the user can observe the analysis results intuitively;
5. The rebound value can be tested. The ultrasonic rebound comprehensive method can be directly connected to the external rebound tester, and the presumed strength of the concrete can be obtained through analysis and settlement. This function applies for national patent.
6. Strong signal receiving ability. The penetration distance of the test in flawless concrete can reach 10 meters;
7. The host directly supplies power to the radial transducer. No external power supply, reliable and stable performance;
8. Standard USB storage device. Large-capacity mobile storage (U disk 1G);
9. Built-in battery power supply. Built-in lithium battery, power supply time up to 6h, if optional external battery, power supply time up to 12 hours, fully meet the customer's long-term testing needs in the field.
10. The instrument is portable. Small size, light weight (about 1.75kg), easy to carry.
11. With extended functions. Scalable shock echo method thickness measurement function (can be used to measure the thickness of concrete on one side);
12. Dual-channel automatic pile measurement to improve the efficiency of pile measurement. It is possible to use dual channels for automatic pile measurement at the same time, which greatly improves the efficiency of pile measurement.
13. Powerful professional windows data analysis and processing software. The external data analysis software has friendly interface and reliable performance. It can directly generate reports for analysis and processing, and can also import the analysis results into word and Excel, which is convenient for users to carry out later data processing.
III.Paramete
Number | Name | Non-Nuclear Soil Density Tester |
1 | Control unit | High-performance embedded industrial computer |
2 | Operation | Keyboard |
3 | Universal interface | USB |
4 | Channel number | Double channel |
5 | Trigger method | Continuous emission, external trigger |
6 | Receive sensitivity | ≤30μv |
7 | Amplifier bandwidth | 5Hz~500 kHz |
8 | Soundtime accuracy | 0.05μs |
9 | Power supply | Built-in high-performance lithium battery, continuous work for 6h |
External high-performance lithium battery, continuous work for 6h (Optional) | ||
12V DC interface | ||
AC 100V~240V,50/60Hz | ||
10 | Display unit | 640×480 Bright TFT true color LCD screen |
11 | storge | 1G(internal)+1G(disc) |
12 | Max lift speed | 60m/min (20cm ranging) |
13 | Max. Sample length | 64k |
14 | Continuous voltage(V) |
65,125,250,500,1000 can choose |
15 | Amplifier gain | 82dB |
16 | Sampling interval (period) | 0.05μs~6.4μs,8gear can adjustment |
17 | Amplitude resolution | 0.39% |
18 | Can add external rebound hammer | yes |
19 | Host Dimension | 260 mm×185 mm×60 mm |
20 | Host weight | 1.75 kg(include the battery ) |
21 | Working temperature | -10ºC-+40ºC |